EasyManua.ls Logo

Uniden BCD396XT - Page 590

Uniden BCD396XT
1059 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Thursday, May 14, 2009
Creating a New System
You can create up to 500 systems.
To create a new system, select the system type from the following items.
MOT Select for any Motorola Type system
EDCS Select for EDACS WIDE/NARROW or EDACS SCAT system
LT Select for an LTR system
Conventional Select for a non-trunked system.
If you select an EDCS type, you need to select more system type information from the following:
WIDE/NARROW Select for an EDACS WIDE/NARROW system
SCAT Select for an EDACS SCAT system
Once you select the system type, the scanner prompts "Confirm?" and "Yes="E" / No="."".
Confi rm?
Yes=”E ” /No=” . ”
Press [E / yes / gps] to confirm, and the system will be created.
Press [. / no / pri] to reject and return to the Menu of Select System.
When the System is created, the scanner assigns a default System name of "System xxx T" to the new
System. (xxx: 1-3 digits sequential number / T: initial of type; MOT="M", EDACS="E", LTR="L",
Conventional="C"). Then, the scanner goes go to Edit System Menu.
Note: Once a system has been created, the system type setting cannot be changed.

Table of Contents