247
<COMMAND CSP>
Get/Set Custom Search Settings
Controller → Radio
CSP,[SRCH_INDEX][\r]
CSP,[SRCH_INDEX],[NAME],[LIMIT_L],[LIMIT_H],[STP],[MOD],[ATT],[DLY],[RSV],
[HLD],[LOUT],[C-CH],[RSV],[RSV],[QUICK_KEY],[START_KEY],[RSV],[NUMBER_TAG],
[RSV],[RSV],[RSV][\r]
Radio → Controller
CSP,[NAME],[LIMIT_L],[LIMIT_H],[STP],[MOD],[ATT],[DLY],[RSV],[HLD],[LOUT], [C-
CH],[RSV],[RSV],[QUICK_KEY],[START_KEY],[RSV],[NUMBER_TAG],[RSV],
[RSV],[RSV][\r]
CSP,OK[\r]
[SRCH_INDEX] : Index (1-9,0 means 10)
[NAME] : Name (max.16char)
[LIMIT_L] : Lower Limit Frequency (250000-13000000)
[LIMIT_H] : Upper Limit Frequency (250000-13000000)
[STP] : Search Step
AUTO : AUTO 833 : 8.33k 2000 : 20k
500 : 5k 1000 : 10k 2500 : 25k
625 : 6.25k 1250 : 12.5k 5000 : 50k
750 : 7.5 k 1500 : 15k 10000 : 100k
[MOD] : Modulation (AUTO/AM/FM/NFM/WFM/FMB)
[ATT] : Attenuation (0:OFF / 1:ON)
[DLY] : Delay Time (-10,-5,-2,0,1,2,5,10,30)
[HLD] : System Hold Time (0-255)
[LOUT] : Lockout (0:Unlocked / 1:Lockout)
[C-CH] : Control Channel Only (0:OFF / 1:ON)
[QUICK_KEY] : Quick Key (0 – 99 / .(dot) )
[START_KEY] : Startup Configuration Key (0 - 9/ .(dot))
[NUMBER_TAG] : Number tag (0-999 / NOE)
Get/Set Custom Search Settings.
In set command, only "," parameters are not changed.
The set command is aborted if any format error is detected.
This command is only acceptable in Programming Mode.

Table of Contents