Chapter 4 _________________________________________________________________ Operation
VAISALA _______________________________________________________________________ 101
FD12 Message 2 Emulation Message
FD 1
00 1850 2000 //// // /////
FD12P Message 7 Emulation Message
FD 1
00 1850 2000 R 61 61 61 0.33 12.16 0
23.3 01100
-RA
RERA
MITRAS Single Baseline Emulation Message
ID 1 V 1850 B 01100 S4101
MITRAS Double Baseline Emulation Message
ID 1 V 1850 B 01100 S410101
Manual Simulation Message
The user can define the entire content of the message body, which is the
string between the
(start of the text) character and the
(end of the
text) character. The message string must be given after the SIMULATE
MANUAL_MESSAGE command in the following way:
SIMULATE MANUAL_MESSAGE string
The FS11P sensor does not make any validity checks to the message
body content which means that the message is transmitted as it is written.
Special characters can be added to the message by using the following
notations:
Message counter (incrementally increased by a sent
message)
Character corresponding to hexadecimal XX