EasyManua.ls Logo

Vaisala FS11P - Replacing;Installing Sensor Cables in FS11 P; Figure 67 FSP103 and FSC202 Sensor Cable Connections

Vaisala FS11P
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User's Guide _______________________________________________________________________
204 __________________________________________________________________ M211107EN-C
Replacing/Installing Sensor Cables in
FS11P
1. Detach the connector side of the cable being replaced.
2. Unthread the cable free from the FS11P sensor arm.
3. Loosen the cable gland.
4. Detach the wiring from the connectors inside FSI102 and remove
the cable.
5. Attach the new cable to the FSI102 and tighten the cable gland; see
Figure 29 on page 56.
6. Connect the wires in their proper places:
- For LM21 cable, see Table 35 on page 205.
- For FSM102 cable, see Table 36 on page 205.
- For PWD32 cable, see Table 37 on page 205.
7. Thread the cable and connect it to the sensor as described in
Chapter 3, Installation, on page 23.
1303-057
Figure 67 FSP103 and FSC202 Sensor Cable Connections
The following numbers refer to Figure 67 above.
1
=
FSP103 X4
2
=
Connection strip

Table of Contents