EasyManua.ls Logo

Vaisala FS11P - Alarm Status Codes; Table 11 Alarm Status Codes

Vaisala FS11P
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4 _________________________________________________________________ Operation
VAISALA ________________________________________________________________________ 81
Alarm Status Codes
The alarm status codes are listed in Table 11 below.
Table 11 Alarm Status Codes
Code
Explanation
Reasons
W
Warning (visibility
measurement value still valid
and shown)
- Window contamination increased
- Transmitter LED aging
- Backup battery voltage low
E
Error (visibility measurement
value NOT shown, replaced
with /////)
- Sensor missing
- Memory error
A
Alarm (visibility measurement
value NOT shown, replaced
with /////)
- Communication error in the
sensor
- Internal monitoring alarm value
exceeded
- Measurement signal saturated or
outside valid range
- Surface temperature
measurement has failed
I
Indication of some abnormal
situation (measurement value
valid and shown)
- AC (mains) off, operating on
battery power
- 12 VDC output in short-circuit
- Hood or dew heater problem
0 (zero)
NO alarm or warning
(alarm is OFF)

Table of Contents

Related product manuals