User's Guide _______________________________________________________________________
190 __________________________________________________________________ M211107EN-C
Replacing FSC102
1. Open the central compartment cover of the visibility sensor, see
Figure 53 on page 191.
2. Make sure that the power is switched off, including battery power.
3. Disconnect the (5 pcs.) terminal plugs.
4. Disconnect the transmitter and receiver control cables. Use the
special tool to unlock the connectors.
5. Remove the four visibility sensor controller mounting screws.
Figure 52 Visibility Sensor Controller (FSC102)
6. Remove the FSC102 carefully from the central compartment and
insert spare item. Pay attention to the cable routing in order not to
stress or damage any wires.
7. Insert and tighten the four mounting screws.
8. Re-connect (5 pcs) terminal plugs. Pay attention to the correct
order.
- Start with terminal #1 (see Figure 52 above).
- Numbers increase counter-clockwise.
9. Connect transmitter and receiver control cable plugs. Pay attention
that the connector locking mechanism has arrested.
Terminal Plug
Terminal Plugs
Transmitter
Control Cable
Receiver
Control Cable
Four Mounting
Screws
Terminal #1

Table of Contents