Chapter 6 _______________________________________________________________ Maintenance 
 
VAISALA _______________________________________________________________________ 187 
Replacing Fuses 
Interface Unit FSI102 contains a two-pole circuit breaker in the AC 
(mains) line, mounted on a DIN rail. Both the phase and return lines go 
through the circuit breaker. The secondary side of the transformer is fuse 
protected by four glass tube fuses: one in the DC voltage line and three 
for heaters (LM21 5 Amps, PWD32 5 Amps, and FSM102 10 Amps). 
The fuses are located on the FSP103 board. The fuse holders are visible 
through a transparent plastic shield covering the live circuits, see Figure 
51 on page 188. 
To replace the fuses, proceed as follows: 
CAUTION 
AC (mains) circuit breaker OFF before replacing 
. 
 
1.  Switch off the AC (mains) circuit breaker. 
2.  Remove the plastic protector shield from FSP103. 
3.  Remove the broken fuse. 
4.  Replace the fuse with a spare (a 10 A for the FSM102 heater line 
and a slow 5 A for the LM21 and PWD32 heater lines). The spares 
are stored in a plastic bag attached to the power cable inside the 
interface unit's enclosure. 
5.  Attach the plastic protector shield back to the FSP103 board. 
6.  Turn the AC (mains) circuit breaker back on and verify that all four 
LEDs are lit on the FSP103 board to indicate that all heater supply 
lines as well as the DC power supply are OK.