EasyManua.ls Logo

Vaisala FS11P - Page 162

Vaisala FS11P
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User's Guide _______________________________________________________________________
160 __________________________________________________________________ M211107EN-C
Temperatures:
Surface
=
FSM102 external temperature
CPU
=
FSC101 temperature
RX
=
FSR102 temperature
TX
=
FST102 temperature
Hood RX
=
Receiver hood temperature
Hood TX
=
Transmitter hood temperature
Voltages:
+12 V
=
Regulated positive operating voltage for
transmitter, receiver, and FSC101
-12 V
=
Regulated negative operating voltage for
transmitter and receiver
VB
=
Voltage which +12 V is regulated from
VR
=
Voltage which +5 V is regulated from
Heater status:
Hood TX
=
TX hood heater automatic control system
on/off, *= heater current flowing
Hood RX
=
RX hood heater automatic control system
on/off, *= heater current flowing
Dew
=
Dew heater automatic control system on/off,
*= heater current flowing
Interface unit
=
FSI102 status
Temperatures:
CPU
=
FSC202 temperature
External
=
FSI102 ext temperature from HMP45D
(option)
Humidity
=
FSI102 ext humidity from HMP45D (option)
Voltages:
+12 V
=
Regulated operating voltage for FSC202
+12 Vout
=
Regulated operating voltage for obstruction
light and HMP45
PVin
=
Supply voltage from either FSP103
(~24 VDC) or backup battery (~12 VDC)
V5I
=
Isolated +5 VDC operating voltage for
RS-485 (on/off)
Background
luminance sensor
=
LM21 status
Window cont
=
Reduction in window transmittance in %
Contamination
compensation
=
Status of background luminance
compensation
Backscatter
=
Signal level from total blockage signal in %
CPU
=
LMB201 temperature
Hood
=
Hood temperature
Heater status
Hood
=
Hood heater automatic control system on/off,
*= heater current flowing
Dew
=
Dew heater automatic control system on/off,
*= heater current flowing

Table of Contents

Related product manuals