Table 41 Operating environment
Property Description/value
Operating temperature for electronics -40 … +60 °C (-40 … +140 °F)
Operating temperature with display -20 … +60 °C (-4 … +140 °F)
Storage temperature -40 … +70 °C (-40 … +158 °F)
Pressure range See probe specifications
Table 42 Compliance
Property Description/value
EMC compatibility EN 613261, industrial environment
Compliance marks CE, China RoHS, RCM,
Table 43 Inputs and outputs
Property Description/value
Operating voltage 12 – 28 V
Analog outputs 2 outputs (two-wire, 4 – 20 mA)
Connection via safety barriers
Typical accuracy of analog outputs at +20 °C ±0.0625 % full scale
Typical temperature dependence of analog
outputs
0.005 % / °C (0.005 % / °F) full scale
Transmitter service port connection USB cable 219690
Probe service port connection USB cable USB2
Display options Graphical LCD display
Model without display (LED indicator)
Table 44 Mechanical specifications
Property Description/value
Connections
Screw terminals, 0.33 … 2.0 mm
2
wires
(AWG 14-22)
Cable glands M20 x 1.5
Conduit fitting NPT 1/2" and M16
Housing material EN AW-6082