Select a strain relief option that suits the application (either use cable glands that include
strain relief or install separate clamps: see IEC 60079-14).
Connect only de-energized wires. Never switch on the power supply
input before completing the wiring and closing the transmitter body.
CAUTION!
Intrinsic safety
The overvoltage category of HMT370EX transmitters is I (non-mains equipment), and ambient
pollution degree is 4, as specified in IEC 60664-1. For intrinsically safe input parameters, see
Table 10 (page 24) .
Table 10  Intrinsically safe input parameters
Parameter Value Associated apparatus entity
parameters
U
i
28 VDC U
o
U
i
I
i
100 mA I
o
I
i
P
i
700 mW P
o
P
i
C
i
12.1 nF C
o
C
i
+ C
cable
L
i
16 µH L
o
L
i
+ L
cable
Using analog output test points
There are test points for measuring the voltages and currents of the analog outputs, located
above each screw terminal block as shown in Figure 6 (page 25). Accessing the test points on
the component board requires opening the transmitter enclosure.