User's Guide ______________________________________________________________________  
148 _________________________________________________________________ M210667EN-C 
outputs a help text. The new system prompt includes the user's 
previous input up to the first parameter requiring clarification. This 
allows the user to complete the command with the correct parameter. 
The help text contains explanations for only those parameters that 
match the operator's input. 
Table 10  User Level Commands 
Command Description 
CLOSE  Releases the port for message transmission. 
DUMP  Prints out a snapshot of the current instrument system 
situation and configuration. 
ECHO  
  ECHO OFF  Disables input character echo. Set off when operating with 
the RS-485 connection. 
  ECHO ON  Enables input character echo (default) 
EVENTS  Gives the events logged by the system. It gives for each 
event listed the following information: 
 - the time of occurrence backward from now by 
   years, months, days, hours, minutes, and  
   seconds 
 - the time of occurrence in operating seconds 
 - the type ( S - single, B bad, or G - good) and 
    the event text is given 
 EVENTS page  The list is given by separate pages. The page length is 
configured by SET TERMINAL_LINES. 
 EVENTS string  The event list is reduced to event which event text contains 
string. 
 EVENTS string page  The reduced event list is given by separate pages. 
HELP Lists available command. 
  HELPcommand  Shows information about a specific command. 
LEVEL 1 
 
or 
 
 
LEVEL 1 [password] 
Changes the operation level to the advanced level. 
 
The password can be given as a parameter. If it is not given 
as a parameter, the user is asked for it. 
 
The default password for the advanced level is LT31 (case 
sensitive). 
MEAS_SYNC  Resets the measurement sequence. The following data 
message is measured starting from the moment all the 
average values are erased. The next message is transmitted 
in seconds (interval +2). 
MENU  Starts the menu-driven operation. For a proper display, the 
terminal application must be set to VT100 emulation. For 
proper operation, the terminal height in lines used by the 
terminal application must be configured to LT31 with the 
command SET TERMINAL_LINES number (minimum 24). 
Also, any 'line wrap'- and 'translate CR to CR/LF' -option 
must be switched off for the terminal application in use. 
MESSAGE  Displays the default message without transmission frames. 
  MESSAGE ALL  LT31 displays all messages. 
 MESSAGE message_number  LT31 displays the selected message with transmission 
frames. 
NAME  Displays the device type, device name given by the user, 
and the ID. 
PARAMETERS  Prints configuration parameters 
SET  
  SET DATA_PORT BAUD number yes/no  Sets data port serial line transmission rate to 300 ... 19200. 
Verification yes/no asked only if the command is given 
through DATA PORT (default 9600).