The background luminance sensor is used for measuring the background 
against which the pilot views the runway lights or runway markings. For 
details on Background Luminance Sensor LM21, refer to LM21 User's 
Guide (see section Related Manuals on page 16). 
TERMBOX-1200/TERMBOX-9000 
The termination box (TERMBOX) acts as the connection point and surge 
protector device for AC power and signal line cables. An AC power 
cable with a maximum diameter of 25 mm can be taken inside the 
termination box. The connector contacts are proper for cable leads up to 
10 mm
2
. 
The Termbox-1200 (LT31 receiver unit) offers connection points and 
surge protectors for two signal lines. 
Surge protectors are available for the following signal line types: 
- Leased-line modem 
- RS-485 
The TERMBOX -9000 (LT31 transmitter unit) offers surge protection for 
the AC power only.  
Obstruction Light LT31OBS 
The obstruction light is equipped with a mounting clamp (see Figure 29 
on page 63). The mounting clamp is mounted to the support arm of the 
LT31 transmitter and receiver support unit.