User's Guide ______________________________________________________________________  
180 _________________________________________________________________ M210667EN-C 
The receiver status correspondence between MITRAS and LT31 is the 
following: 
 BIT  MITRAS  LT31 
 BIT.0=1 MEAS MODE  ON 
IV BIT.1=2 CONT/OTHER  Any other LT31 alarm 
 BIT.2=4 OPTICAL SURFACE  OFF 
 BIT.3=8 POWER SUPPLY  OFF 
 BIT.4=1 HEATING  OFF 
III BIT.5=2 CALIBRATION  Receiver saturated 
 BIT.6=4 TEST  OFF 
 BIT.7=8 CONSISTENCY  OFF 
 
For example, status 4101 means that 
I  4 = BL sensor ON 
II  1 = ON 
IV  1 = ON 
 
In other words, Background Luminance Sensor LM21 is set as the 
background luminance sensor. 
Message 8 - Flamingo Emulation 
For compatibility in the system level, LT31 also supports the message 
format, frames, and polling format of Impulsphysik transmissometer 
SKOPOGRAPH II “Flamingo”. The FLAMINGO polling format is 
accepted only when the FLAMINGO message emulation is selected. The 
FLAMINGO emulation mode is selected with the SET MESSAGE 
TYPE SKOPO2 command.  
The FLAMINGO polling format is as follows: 
"H0C!S0P_ _ _ _ _ _ _ _ _ _0B$ 
NOTE 
Read the ' _ ' character as a space.