Firmware Designation
VLB Firmware: bright blue v. Y.X.X
Y - Represents the embedded firmware version (matching the software application version)
X.X -- Sequential numbers representing the embedded firmware feature upgrades
VBB-RI Firmware: g1_0.XX
XX numbers values represents the embedded firmware feature upgrades.
VBB-NRI Firmware: g4_0.XX
XX numbers values represents the embedded firmware feature upgrades.
UL Evaluated Firmware
UL has evaluated firmware 2.0.0 in the VBB
UL has evaluated firmware g1_0.05 in the SBB-RI (Legacy)
UL has evaluated firmware FV11 in the VBB-RI
UL has evaluated firmware g4_0.08 in the VBB-NRI
The following should be incorporated into the system:
The UL 294 requires the lite blue controller enclosure and the VBB-RI enclosure to have a tamper switch
that will generate an alarm whenever the enclosure is opened. Connect the tamper switch flying leads to a
UL Listed burglar alarm system or UL Listed local siren/annunciator.
Note: UL has only evaluated the system for stand-alone operation. The connection to a PC/Web browser is to be
employed as a local programming/downloading/monitoring tool only.
Operation Testing and Maintenance
Operation Testing
Once lite blue and system components are installed, log into the system and set up a cardholder with a
credential and access. Present that credential at read head to test. A green LED indicates system is working.
Maintenance
No regular maintenance is required, lite blue and system components are self-supporting.