Frequency agility for increased interference immunity
Addressing
Card formats
The PIM400-485-VBB accepts card formats up to 255 bits.
Operational environment
Temperature: -35°C to +66°C
Humidity: 20% RH to 95% RH (non-condensing)
Operating Voltage: 12 to 24 VDC (Powered from lite blue or locally)
Power consumption: 300mA max.
Radio frequency (RF) - The PIM400 includes an RF Transceiver
Spread spectrum
Direct sequencing spread spectrum
Frequency: 902-928 MHz
Data Rate: 62.5 kbps (half duplex)
Modulo 256 error detection
Selectable channels: 1 of 15 standard; 5 groups of 3 increased interference immunity (configurable)
Approvals: FCC and RSS-210 (Canada)
Transmitter Power: Up to 300mW
Receiver Sensitivity: 90dBM typical
Specifications for the PIM400-485-VBB
RS-485 Communication to lite blue controller
Supports 16 Wireless Devices
No SRINX is required
lite blue can support multiple PIM400-485-VBB
AD-400 Series Wireless Locks
Schlage AD-400 Series locks
contain all of the elements needed to electronically control and monitor access
through a door via an RF link. The lock includes a lockset, a Request-to-Exit sensor/switch, a Request-to-Enter
sensor/ switch, a power supply (battery pack), and terminals for monitoring a clutch position switch/sensor, a card
reader, and an RF transceiver for communicating with another RF transceiver in a Panel Interface Module
(PIM400) which then interfaces to lite blue.
Performance
Verification Time: Typically 0.2 seconds including lock actuation time but not including access panel delays
Communications (Heartbeat)
Wake Up on Radio - Allows the PIM400 to alert the AD-400 locks in case of a Lockdown event.
Addressing
Card reader - Magnetic Stripe Card Reader
ANSI/BHMA A156.25 compliant Track 2 Clock & Data Output (Some card code conversions available)
Read Rate - 3 – 50 inches per second