EasyManua.ls Logo

Vanderbilt lite blue - SBB-RI Enclosure; Features; Environmental Conditions; Mounting

Vanderbilt lite blue
152 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
60 lite blue Installation Manual
SBB-RI Enclosure
SBB-RI Enclosure - An enclosure with a hinged door is included for each SBB-RI. The flying leads of the
tamper switch should be attached to a UL Listed burglar alarm system or Listed local siren/annunicator.
Features
Metal enclosure with hinged door
Enclosure Dimensions: 8.25” x 7.5” x 3.5”
Environmental conditions
Ambient Temperature: 0º to 49º C or 32º to 120º F
The room must be dust free and clean.
It is optimal to mount the enclosure on fire rated plywood which is affixed to a cinder block wall or a wall
covering i.e. sheetrock
Mount the cabinet in a secure, but generally accessible location
Mounting
Field Wiring - It is necessary to punch the knockouts in the metal enclosure for field wiring. It is
recommended that this is done before mounting the enclosure to the wall.
A non-metallic sleeve is recommended to protect the wiring where it enters the cabinet.
Mount the enclosure to the wall using the provided mounting holes. Recommended mounting hardware:
Four 1/4” x 1” lag bolts.
To secure the SBB-RI enclosure use two screws through the openings provided on the cover. Alternately a
lock can be added using the provided punch out section on the cover.