D7x11 Series II Navigator Directional Drill Preparation 40-13
Remote Lockout System - Test
IMPORTANT: Test Remote Lockout system at least once daily and at the start of every bore. Machine operator
must be seated for machine to be in Drill mode. Remote Lockout system does not work in Transport mode.
Complete the following steps with transmitter located near the machine.
Step 1: Start engine and turn on remote transmitter.
Step 2: Press Lockout Button on remote transmitter. The red light must come on and buzzer must sound 9
beeps to indicate that the machine is locked out.
Step 3: Machine operator must attempt to begin drilling. Drilling functions should remain stopped (locked
out).
Step 4: Press Run Button and hold for 2 seconds. Green light comes on, and buzzer sounds for 2 seconds.
Operator will be able to resume drilling.
If test is not successful, ensure transmitter is within range and that machine is running and is in Drill mode
(operator seated at controls). If a problem still exists, contact your Vermeer dealer to determine source, and use
the “Lockout Procedure - Without Remote Lockout System,” page 30-13, until the Remote Lockout system is
repaired. NOTE: The Remote Lockout system is not operational when machine is in Transport mode.