2. System Programming – P1…..P10 (in the example P3 Cappuccino)
1. Product counter – indicates by what number the counter is increased in the coffee ma-
chine statistics if beverage is dispensed, value must not be modified.
2. Number of cycles – this value indicates how often the beverage dispensing is repeated
per touch of the beverage button, value must not be modified.
3. Pause for multiple dispensing – indicates how long the pause is between multiple dis-
pensing (see number of cycles), value must not be modified.
4. Valve pre-heating – this value indicates how much rinsing water is used for pre-heating
the coffee machine, value must not be modified.
5. Grinding amount – this value indicates how much ground coffee (gr.) is used for this
beverage; value should only be modified at the coffee machine.
6. Double product grinding time extension – if a double beverage is dispensed in only one
brewing cycle, this value indicates by how many percent (compared to the single bever-
age) the grinding quantity is increased, value must not be modified.
7. Pre-infuse dosage – this value indicates how much water is used for the pre-brewing
function, value must not be modified.
8. Delay after pre-infusion – this value indicates, how long the brewing is delayed, value
must not be modified.
9. Open brewing chamber – this value indicates how long the brewing chamber is opened
for brewing in order to reach a better brewing time, value must not be modified.
10. Tamping pressure coffee – this value indicates, how much the ground coffee is pressed
in the brewing chamber, value must not be modified.
11. Coffee water dosage – this value indicates how much water (ml) is used for this bever-
age; value should only be modified at the coffee machine.