Cleaning and care
© WMF800 / 900 / 1000S / 1000proS Edition 07/2014 - KMT
T3-4
3/9 Scale filter insert
The use of awater filter is recommended with awater hardness of more than 5 °dH.
Replacing the water filter is requested in accordance with the following table or after
90days.
Filter capacity, water filter 100
(liters)
Filter capacity, water filter
200(liters)
Water hardness (°dH)
0 0 0 - 4
125 250 5 - 8
85 170 9 - 12
62 124 13 - 16
40 80 > 16
The 200water filter can be used only with the WMF1000S and 1000proSin
conjunction with the ofce function. The 200water filter is not used with the
WMF800and 900.
3/10 Cleaning intervals overview
Care
Daily
Weekly
Regularly
Required
Optional
automatically /
as required
Description, see
x
Warm-up rinse/coffee system
rinse
User Manual
x All-in-One spout cleaning User Manual
x x Milk system rinse Connect&Clean User Manual
x Milk system cleaning User Manual
x x Coffee machine cleaning User Manual
x Brewing unit cleaning User Manual
x x Grounds container cleaning User Manual
x Water tank cleaning User Manual
x Drip tray cleaning User Manual
x Bean hopper cleaning User Manual
x Casing cleaning User Manual
x O Filter change User Manual
x Descaling User Manual
Daily = Daily, at least once per day and as required
Weekly = Weekly cleaning
Regularly = Regularly as required
Required = As required
Optional = Optional (depending on the model)
(x) = Daily as required