EasyManua.ls Logo

Xerox B210 - Installing Software

Xerox B210
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
July 2019
2-14
Xerox® B210 Service Manual
10-100 , 10-200/ 300
Initial Release
Status Indicator RAPs
10-100 Fuser Temperature (Open) RAP
BSD-ON:BSD 1
The temperature of the Fuser is outside of the normal operating range of 383°F ± 5°F (195°C ±
C.)
Initial Actions
Switch off, then switch on the machine.
Procedure
WARNING
Do not handle the fuser components until they have cooled. Some fuser components
operate at hot temperatures and can produce serious personal injury if touched.
DANGER: Ne pas manipuler les éléments du four avant de les laisser refroidir. Certains
él
éments du four fonctionnent à des températures très élevées et peuvent causer de
graves blessures s'ils sont touchés.
AVVERTENZA: Non maneggiare i componenti del fusore finché non sono raffreddati.
Al
cuni di questi componenti funzionano ad alte temperature e possono provocare gravi
ferite se vengono toccati.
VORSICHT: Die Fixieranlage sollte erst gehandhabt werden, wenn diese genügend
a
bgekühlt ist. Einige Teile der Fixieranlage erzeugen übermäßige Hitze und führen bei
der Berührung zu schweren Verbrennungen.
AVISO: No manipule los componentes del fusor antes de que se enfríen. Algunos de los
co
mponentes del fusor funcionan a altas temperaturas y pueden ocasionar daños per-
sonales graves si se los toca.
Switch off the machine, then verify the Fuser is fully seated, P
L 5.1 Item 26. The Fuser con-
nections are OK.
YN
Check the Fuser connections for contamination and clean as required.
Firmly reconnect the Fuser Module. Switch the power on,
Check for +3.3 VDC to the Thermistor on Main PWB. The voltage is present.
YN
Check the wire harness for open or short circuits.
Install a new Main PWB, PL 1.
1 Item 7.
Check the voltage to the Over Heat Thermostat. The voltage is present.
YN
Check for AC line voltage to the LVPS PWB, P
L 4.4 Item 3.
Check the Over Heat thermostat for contamination.
Check the wire harness from the LVPS PWB for open or short circuits.
Install a new LVPS PWB, P
L 4.4 Item 3.
Check the circuits and connectors for the Fuser Module.
Check the Heat Lamp for an open circuit.
Install a new Fuser Module, PL 5.
1 Item 26.
10-200/ 300 Fuser Under/ Over Temperature RAP
BSD-ON:BSD 1
The temperature of the Fuser is outside of the normal operating range of 383°F ± 5°F (195°C ±
5°C
.)
Initial Actions
Switch off the machine. Remove and reinstall the Fuser Assembly. Switch On the power.
Procedure
WARNING
Do not handle the fuser components until they have cooled. Some fuser components
operate at hot temperatures and can produce serious personal injury if touched.
DANGER: Ne pas manipuler les éléments du four avant de les laisser refroidir. Certains
él
éments du four fonctionnent à des températures très élevées et peuvent causer de
graves blessures s'ils sont touchés.
AVVERTENZA: Non maneggiare i componenti del fusore finché non sono raffreddati.
Al
cuni di questi componenti funzionano ad alte temperature e possono provocare gravi
ferite se vengono toccati.
VORSICHT: Die Fixieranlage sollte erst gehandhabt werden, wenn diese genügend
a
bgekühlt ist. Einige Teile der Fixieranlage erzeugen übermäßige Hitze und führen bei
der Berührung zu schweren Verbrennungen.
AVISO: No manipule los componentes del fusor antes de que se enfríen. Algunos de los
co
mponentes del fusor funcionan a altas temperaturas y pueden ocasionar daños per-
sonales graves si se los toca.
1. If problem is intermittent, check the circuit of the Fuser Module for one of the following:
All connectors are securely connected
and no contamination is present.
Short circuit or damaged wire, repair as necessary.
2. Install a new Fuser Module, PL 5.
1 Item 26.

Table of Contents