9-231
P1602
EAS20615
P1602
EAS33095
TROUBLESHOOTING
Item
Malfunction in ECU internal circuit (malfunction of ECU power cut-off function).
Fail-safe system
Able/Unable to start engine
Able/Unable to drive vehicle
Procedure
1. Installed condition of battery leads.
Check the installed condition of the battery and battery leads (loose bolts).
2. Connection of starter relay coupler.
Check the locking condition of the coupler.
Disconnect the coupler and check the pins (bent or broken terminals and locking condition of the
pins).
3. Connection of main switch coupler.
Check the locking condition of the coupler.
Disconnect the coupler and check the pins (bent or broken terminals and locking condition of the
pins).
Is check result OK?
YES
Go to step 2.
NO
a. Reinstall or replace the battery leads.
b. Turn the main switch to “ON”, and then check the condition of the DTC using the malfunction
mode of the YDT.
Is it in the “Recovered” condition?
YES
Go to step 7, and complete the service.
NO
Go to step 2.
Is the coupler condition normal?
YES
Go to step 3.
NO
a. Connect the coupler securely or replace the wire harness.
b. Turn the main switch to “ON”, and then check the condition of the DTC using the malfunction
mode of the YDT.
Is it in the “Recovered” condition?
YES
Go to step 7, and complete the service.
NO
Go to step 3.