5.1 Manipulating Parameters (Pn)
5.1.1 Parameter Classification
5-4
5.1
Manipulating Parameters (Pn)
This section describes the classifications, notation, and setting methods for the parameters
given in this manual.
5.1.1
Parameter Classification
There are the following two types of SERVOPACK parameters.
The setting method for each type of parameter is described below.
Setup Parameters
You can use the Panel Operator, Digital Operator, or SigmaWin+ to set the setup parameters
individually.
Classification Meaning
Setup Parameters
Parameters for the basic settings that are
required for operation.
Tuning Parameters
Parameters that are used to adjust servo
performance.
The tuning parameters are not displayed by default when you use the Panel Operator or Digital
Operator. To display and set the tuning parameters, set Pn00B to n.

1 (Display all parame-
ters).
We recommend that you use the Setup Wizard of the SigmaWin+ to easily set the required setup
parameters by setting the operating methods, machine specifications, and I/O signals according
to on-screen Wizard instructions.
Information
Parameter Meaning When Enabled Classification
Pn00B
n.

0
(default setting)
Display only setup parameters.
After restart Setup
n.

1
Display all parameters.
Information