Step
Panel Display after
Operation
Keys Operation
1
Press the MODE/SET Key to enter Utility Function
Mode.
2 Press the UP Key or DOWN Key to display Fn008.
3
Press the DATA/SHIFT Key for approximately one
second. PGCL1 will be displayed.
4
Continue pressing the UP Key until PGCL5 is dis-
played.
Note: If you press the wrong key, no-oP will flash
on the display for approximately one second
and the display will return to the original Util-
ity Function Mode display. Repeat the opera-
tion from the beginning.
5
Press the MODE/SET Key.
The absolute encoder will be initialized.
When initialization has been completed, donE will
flash on the display for approximately one second.
6
After displaying donE, the display will return to the
PGCL5 display.
7
Press the DATA/SHIFT Key for approximately one
second to return the display to Fn008.
8 To enable the change to the settings, turn the power supply to the SERVOPACK OFF and ON again.