13.4 Utility Function (Fn) Operations on the Panel Operator
13.4.13 Autotune Motor Current Detection Signal Offset (Fn00E)
13-21
13
Panel Displays and Panel Operator Procedures
13.4.13
Autotune Motor Current Detection Signal Offset (Fn00E)
Refer to the following section for information on this utility function other than the procedure.
6.16.1 Automatic Adjustment on page 6-101
5 Press the UP Key or DOWN Key to adjust the gain.
6
Press the DATA/SHIFT Key. The display shown on the
left will appear again.
7
Press the MODE/SET Key. The display will change
from the monitor output for channel 1 to the monitor
output for channel 2.
8
Press the DATA/SHIFT Key. The gain adjustment will
be displayed as shown on the left.
9 Press the UP Key or DOWN Key to adjust the gain.
10
Press the DATA/SHIFT Key for approximately one sec-
ond. Ch2-G will be displayed, and then Fn00D will be
displayed again.
Continued from previous page.
Step
Panel Display after
Operation
Keys Operation
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/
Step
Panel Display after
Operation
Keys Operation
1
Press the MODE/SET Key to enter Utility Function
Mode.
2 Press the UP Key or DOWN Key to display Fn00E.
3
Press the DATA/SHIFT Key for approximately one sec-
ond. The display shown at the left will appear.
4
Press the MODE/SET Key to perform automatic off-
set-signal adjustment. When the adjustment has been
completed, donE will flash on the display, and then the
display shown on the left will appear again.
5
Press the DATA/SHIFT Key for approximately one sec-
ond to return the display to Fn00E.
MODE
/
SET
DATA
/
MODE
/
SET
DATA
/