5.1 Manipulating Parameters (Pn)
5.1.4 Write Prohibition Setting for Parameters
5-9
5
Basic Functions That Require Setting before Operation
5.
Click the OK Button.
The setting will be written to the SERVOPACK.
6.
To enable the new setting, turn the power supply to the SERVOPACK OFF and ON
again.
This concludes the procedure to prohibit or permit writing parameter settings.
Restrictions
If you prohibit writing parameter settings, you will no longer be able to execute some functions.
Refer to the following table.
SigmaWin+ Panel Operator or Digital Operator
When Writ-
ing Is Pro-
hibited
Reference
Button in
Menu
Dialog Box
SigmaWin+ Function
Name
Fn No. Utility Function Name
Setup
Origin Search
Fn003 Origin Search
Cannot be
executed.
page 7-25
Absolute Encoder Reset Fn008 Reset Absolute Encoder
Cannot be
executed.
page 5-53
Speed/Torque Reference
Offset Adjustment
Fn009
Autotune Analog (Speed/
Torque) Reference Offset
Cannot be
executed.
page 6-23,
page 6-40
Fn00A
Manually Adjust Speed Refer-
ence Offset
Cannot be
executed.
page 6-23
Fn00B
Manually Adjust Torque Ref-
erence Offset
Cannot be
executed.
page 6-40
Analog Monitor Output
Adjustment
Fn00C
Adjust Analog Monitor Output
Offset
Cannot be
executed.
page 9-10
Fn00D
Adjust Analog Monitor Output
Gain
Cannot be
executed.
page 9-10
Motor Current Detection
Offset Adjustment
Fn00E
Autotune Motor Current
Detection Signal Offset
Cannot be
executed.
page 6-101
Fn00F
Manually Adjust Motor Cur-
rent Detection Signal Offset
Cannot be
executed.
Multiturn Limit Setting
Fn013
Multiturn Limit Setting after
Multiturn Limit Disagreement
Alarm
Cannot be
executed.
page 6-83
Reset Configuration Error
of Option Module
Fn014
Reset Option Module Config-
uration Error
Cannot be
executed.
page 12-43
Initialize Vibration Detection
Level
Fn01B
Initialize Vibration Detection
Level
Cannot be
executed.
page 6-97
Set Origin Fn020
Set Absolute Linear Encoder
Origin
Cannot be
executed.
page 5-55
Software Reset Fn030 Software Reset
Can be
executed.
page 6-95
Polarity Detection Fn080 Polarity Detection
Cannot be
executed.
page 5-31
Tuning-less Level Setting Fn200 Tuning-less Level Setting
Cannot be
executed.
page 8-16
EasyFFT Fn206 Easy FFT
Cannot be
executed.
page 8-93
Continued on next page.