5.13 Holding Brake
5.13.4 Output Timing of /BK (Brake) Signal When the Servomotor Is Operating
5-41
5
Basic Functions That Require Setting before Operation
When the Time Set In Pn508 Elapses after the Power Supply to the Motor Is Stopped
The Servomotor will be limited to its maximum speed even if the brake reference output speed
level (Rotary Servomotor: Pn507, Linear Servomotor: Pn583) is higher than the maximum speed.
ON
OFF
Rotary Servomotor: Pn507
Linear Servomotor: Pn583
Motor stopped with dynamic
brake or by coasting
(Pn001 = n.X)
Power
supplied.
Power not supplied.
OFF (Brake
applied.)
Motor speed
Motor power status
/BK signal
/S-ON input, alarm,
or power OFF
Pn508
ON (Brake released.)