EasyManua.ls Logo

YASKAWA SGD7S - Page 216

YASKAWA SGD7S
621 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.5 Speed Control
6.5.1 Basic Settings for Speed Control
6-21
6
Application Functions
This concludes the procedure to automatically adjust the speed reference offset.
Manually Adjusting the Speed Reference Offset
You can directly input a speed reference offset to adjust the speed reference. The offset is
adjusted manually in the following cases.
When a position loop is created with the host computer and the position deviation when the
Servomotor is stopped by a servo lock is to be set to 0
To intentionally set the offset to a desired value
To check an offset that was set automatically
Preparations
The following conditions must be met to manually adjust the reference offset.
The parameters must not be write prohibited.
The servo must be in ready status.
Applicable Tools
The following table lists the tools that you can use to manually adjust the speed reference offset
and the applicable tool functions.
The offset does not use a parameter, so it will not change even if the parameter settings are
initialized.
Tool Function Operating Procedure Reference
Panel Operator Fn00A
13.4.9
Manually Adjust Speed Reference Offset (Fn00A)
on
page 13-18
Digital Operator Fn00A
Σ-7-Series Digital Operator Operating Manual (Manual
No.: SIEP S800001 33)
SigmaWin+
Setup - Speed/Torque Ref-
erence Offset Adjustment
Operating Procedure on page 6-22
Information

Table of Contents

Related product manuals