6.7 Torque Control
6.7.2 Adjusting the Torque Reference Offset
6-42
The value that results from automatic adjustment will be displayed in the New Box.
Note: You cannot automatically adjust the reference offset if a position loop is created with the host controller. Man-
ually adjust the torque reference offset.
This concludes the procedure to automatically adjust the torque reference offset.
Manually Adjusting the Torque Reference Offset
You can directly input a torque reference offset to adjust the torque reference. The offset is
adjusted manually in the following cases.
To intentionally set the offset to a desired value
To check an offset that was set automatically
Preparations
The following conditions must be met to manually adjust the reference offset.
The parameters must not be write prohibited.
The servo must be in ready status.
Applicable Tools
The following table lists the tools that you can use to manually adjust the torque reference off-
set and the applicable tool functions.
The offset does not use a parameter, so it will not change even if the parameter settings are
initialized.
Tool Function Operating Procedure Reference
Panel Operator Fn009
13.4.10 Manually Adjust Torque Reference Offset
(Fn00B) on page 13-19
Digital Operator Fn009
Σ-7-Series Digital Operator Operating Manual (Manual
No.: SIEP S800001 33)
SigmaWin+
Setup - Speed/Torque Ref-
erence Offset Adjustment
Operating Procedure on page 6-43