7.1 Flow of Trial Operation
7.1.1 Flow of Trial Operation for Rotary Servomotors
7-3
7
Trial Operation and Actual Operation
• Trial Operation
Step
Meaning Reference
1
Trial Operation for the Servomotor without
a Load
7.3 Trial Operation for the Servomotor without a Load
on page 7-7
2
Trial Operation from the Host Controller for
the Servomotor without a Load
7.4 Trial Operation from the Host Controller for the Ser-
vomotor without a Load on page 7-10
3
Trial Operation with the Servomotor Con-
nected to the Machine
7.5 Trial Operation with the Servomotor Connected to
the Machine on page 7-17
To power
supply
Secure the motor ange to the
machine. Do not connect the
motor shaft to the load shaft.
To power
supply
CN1
To host controller
Secure the motor ange to the
machine. Do not connect the
motor shaft to the load shaft.
To power
supply
CN1
To host controller
Secure the motor ange to the
machine, and connect the
motor shaft to the load shaft
with a coupling or other means.