7.6 Convenient Function to Use during Trial Operation
7.6.1 Program Jogging
7-23
7
Trial Operation and Actual Operation
• Linear Servomotors
Applicable Tools
The following table lists the tools that you can use to perform program jogging and the applica-
ble tool functions.
Pn530
Program Jogging-Related Selections
Setting Range Setting Unit Default Setting When Enabled Classification
0000 to 0005 − 0000 Immediately Setup
Pn531
Program Jogging Travel Distance
Setting Range Setting Unit Default Setting When Enabled Classification
1 to 1,073,741,824 1 reference unit 32,768 Immediately Setup
Pn585
Program Jogging Movement Speed
Setting Range Setting Unit Default Setting When Enabled Classification
1 to 10,000 1 mm/s 50 Immediately Setup
Pn534
Program Jogging Acceleration/Deceleration Time
Setting Range Setting Unit Default Setting When Enabled Classification
2 to 10,000 1 ms 100 Immediately Setup
Pn535
Program Jogging Waiting Time
Setting Range Setting Unit Default Setting When Enabled Classification
0 to 10,000 1 ms 100 Immediately Setup
Pn536
Program Jogging Number of Movements
Setting Range Setting Unit Default Setting When Enabled Classification
0 to 1,000 1 1 Immediately Setup
Tool Function Reference
Panel Operator Fn004
13.4.4 Jog Program (Fn004) on page 13-15
Digital Operator Fn004
Σ-7-Series Digital Operator Operating Manual
(Manual No.: SIEP S800001 33)
SigmaWin+ Test Run - Program JOG Operation
Operating Procedure on page 7-24