12.2 Alarm Displays
12.2.1 List of Alarms
12-6
A.041
Encoder Output Pulse
Setting Error
The setting of Pn212 (Num-
ber of Encoder Output
Pulses) or Pn281 (Encoder
Output Resolution) is outside
of the setting range or does
not satisfy the setting condi-
tions.
Gr.1 No HHH
A.042
Parameter Combination
Error
The combination of some
parameters exceeds the set-
ting range.
Gr.1 No HHH
A.044
Semi-Closed/Fully-Closed
Loop Control Parameter
Setting Error
The settings of the Option
Module and Pn002 =
n.X (External Encoder
Usage) do not match.
Gr.1 No HHH
A.050 Combination Error
The capacities of the
SERVOPACK and Servomo-
tor do not match.
Gr.1 Yes HHH
A.051
Unsupported Device
Alarm
An unsupported device was
connected.
Gr.1 No HHH
A.070
Motor Type Change
Detected
The connected motor is a dif-
ferent type of motor from the
previously connected motor.
Gr.1 No HHH
A.080
Linear Encoder Pitch Set-
ting Error
The setting of Pn282 (Linear
Encoder Scale Pitch) has not
been changed from the
default setting.
Gr.1 No HHH
A.0b0
Invalid Servo ON Com-
mand Alarm
The /S-ON (Servo ON) signal
was input from the host con-
troller after a utility function
that turns ON the Servomo-
tor was executed.
Gr.1 Yes HHH
A.100 Overcurrent Detected
An overcurrent flowed
through the power transistor
or the heat sink overheated.
Gr.1 No L H H
A.101
Motor Overcurrent
Detected
The current to the motor
exceeded the allowable cur-
rent.
Gr.1 No L H H
A.300 Regeneration Error
There is an error related to
regeneration.
Gr.1 Yes L L H
A.320 Regenerative Overload
A regenerative overload
occurred.
Gr.2 Yes L L H
A.330
Main Circuit Power Supply
Wiring Error
The AC power supply input
setting or DC power supply
input setting is not correct.
The power supply wiring is
not correct.
Gr.1 Yes L L H
A.400 Overvoltage
The main circuit DC voltage
is too high.
Gr.1 Yes H H L
A.410 Undervoltage
The main circuit DC voltage
is too low.
Gr.2 Yes H H L
A.510 Overspeed
The motor exceeded the
maximum speed.
Gr.1 Yes L H L
Continued on next page.
Continued from previous page.
Alarm
Number
Alarm Name Alarm Meaning
Servo-
motor
Stop-
ping
Method
Alarm
Reset
Possi-
ble?
Alarm Code
Output
ALO1 ALO2 ALO3