EasyManua.ls Logo

YASKAWA SGD7S

YASKAWA SGD7S
621 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12.2 Alarm Displays
12.2.1 List of Alarms
12-11
12
Maintenance
* These alarms are not stored in the alarm history. They are only displayed on the panel display.
Note: The A.Eb0, A.Eb2 to A.Eb9, and A.EC0 to A.EC2 alarms can occur when a Safety Module is connected.
Refer to the following manual for details.
AC Servo Drive
Σ
-V-Series/
Σ
-V-Series for Large-Capacity Models/
Σ
-7-Series User’s Manual Safety Module (Manual
No.: SIEP C720829 06)
A.F50
Servomotor Main Circuit
Cable Disconnection
The Servomotor did not
operate or power was not
supplied to the Servomotor
even though the /S-ON
(Servo ON) signal was input
when the Servomotor was
ready to receive it.
Gr.1 Yes H L H
FL-1*
System Alarm
An internal program error
occurred in the SERVO-
PACK.
–NoUndefined.
FL-2*
FL-3*
FL-4*
FL-5*
FL-6*
CPF00
Digital Operator Commu-
nications Error 1
Communications were not
possible between the Digital
Operator (model: JUSP-
OP05A-1-E) and the SERVO-
PACK (e.g., a CPU error
occurred).
–NoUndefined.
CPF01
Digital Operator Commu-
nications Error 2
Continued from previous page.
Alarm
Number
Alarm Name Alarm Meaning
Servo-
motor
Stop-
ping
Method
Alarm
Reset
Possi-
ble?
Alarm Code
Output
ALO1 ALO2 ALO3

Table of Contents