14.1 List of Parameters
14.1.2 List of Parameters
14
Parameter Lists
14-15
Pn162 2
Anti-Resonance Gain
Correction
1 to 1,000 1% 100 All
Immedi-
ately
Tuning
page
8-51
Pn163 2
Anti-Resonance Damp-
ing Gain
0 to 300 1% 0 All
Immedi-
ately
Tuning
page
8-51
Pn164 2
Anti-Resonance Filter
Time Constant 1 Cor-
rection
-1,000 to
1,000
0.01 ms 0 All
Immedi-
ately
Tuning
page
8-51
Pn165 2
Anti-Resonance Filter
Time Constant 2 Cor-
rection
-1,000 to
1,000
0.01 ms 0 All
Immedi-
ately
Tuning
page
8-51
Pn166 2
Anti-Resonance Damp-
ing Gain 2
0 to 1,000 1% 0 All
Immedi-
ately
Tuning
page
8-51
Pn170
2
Tuning-less Function-
Related Selections
0000 to
2711
1401 All Setup
page
8-12
Pn181 2
Mode Switching Level
for Speed Reference
0 to 10,000 1 mm/s 0 Linear
Immedi-
ately
Tuning
page
8-88
Pn182 2
Mode Switching Level
for Acceleration
0 to 30,000
1 mm/s
2
0 Linear
Immedi-
ately
Tuning
page
8-88
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.X
Tuning-less Selection
When
Enabled
0 Disable tuning-less function.
After
restart
1 Enable tuning-less function.
n.X
Speed Control Method
When
Enabled
0 Use for speed control.
After
restart
1 Use for speed control and use host controller for position control.
n.X
Rigidity Level
When
Enabled
0 to 7 Set the rigidity level.
Immedi-
ately
n.X
Tuning-less Load Level
When
Enabled
0 to 2 Set the load level for the tuning-less function.
Immedi-
ately