15.2 Corresponding SERVOPACK and SigmaWin+ Function Names
15.2.2 Corresponding SERVOPACK Monitor Display Function Names
15-9
*1. You can use Un010 to monitor the upper limit setting for the maximum motor speed or the upper limit setting for
the encoder output resolution.
You can monitor the upper limit of the encoder output resolution setting (Pn281) for the current maximum motor
speed setting (Pn385), or you can monitor the upper limit of the maximum motor speed setting for the current
encoder output resolution setting.
Select which signal to monitor with Pn080 = n.X (Calculation Method for Maximum Speed or Encoder
Output Pulses).
Motion
Monitor
Fully-closed Loop Feedback Pulse
Counter [external encoder resolu-
tion]
Un00E
Fully-closed Loop Feedback Pulse Counter
[external encoder resolution]
Upper Limit Setting of Motor Maxi-
mum Speed/Upper Limit Setting of
Encoder Output Resolution
Un010
*1
Upper Limit Setting of Motor Maximum Speed/
Upper Limit Setting of Encoder Output Resolu-
tion
Total Operation Time [100 ms] Un012 Total Operation Time [100 ms]
Feedback Pulse Counter [reference
units]
Un013 Feedback Pulse Counter [reference units]
Power Consumption [W] Un032 Power Consumption [W]
Consumed Power [0.001 Wh] Un033 Consumed Power [0.001 Wh]
Cumulative Power Consumption
[Wh]
Un034 Cumulative Power Consumption [Wh]
Absolute Encoder Multiturn Data Un040 Absolute Encoder Multiturn Data
Position within One Rotation of
Absolute Encoder [encoder pulses]
Un041
Position within One Rotation of Absolute
Encoder [encoder pulses]
Lower Bits of Absolute Encoder
Position [encoder pulses]
Un042
Lower Bits of Absolute Encoder Position
[encoder pulses]
Upper Bits of Absolute Encoder
Position [encoder pulses]
Un043
Upper Bits of Absolute Encoder Position
[encoder pulses]
Status
Monitor
Polarity Sensor Signal Monitor Un011 Polarity Sensor Signal Monitor
Active Gain Monitor Un014
Effective Gain Monitor (gain settings 1 = 1, gain
settings 2 = 2)
Safety I/O Signal Monitor Un015 Safety I/O Signal Monitor
Input Sig-
nal Moni-
tor
Input Signal Monitor Un005 Input Signal Monitor
Output
Signal
Monitor
Output Signal Monitor Un006 Output Signal Monitor
Service
Life Moni-
tor
Installation Environment Monitor −
SERVOPACK
Un025
SERVOPACK Installation Environment Monitor
[%]
Installation Environment Monitor −
Servomotor
*2
Un026
*2
Servomotor Installation Environment Monitor
[%]
Service Life Prediction Monitor −
Built-in Fan
Un027 Built-in Fan Remaining Life Ratio [%]
Service Life Prediction Monitor −
Capacitor
Un028 Capacitor Remaining Life Ratio [%]
Service Life Prediction Monitor −
Surge Prevention Circuit
Un029
Surge Prevention Circuit Remaining Life Ratio
[%]
Service Life Prediction Monitor −
Dynamic Brake Circuit
Un02A Dynamic Brake Circuit Remaining Life Ratio [%]
Product
Informa-
tion
Motor − Resolution
Un084
Linear Encoder Pitch (Scale pitch = Un084 ×
10
Un085
[pm])
Un085
Linear Encoder Pitch Exponent (Scale pitch =
Un084 × 10
Un085
[pm])
–
– Un020
Rated Motor Speed [min
-1
]
– Un021
Maximum Motor Speed [min
-1
]
Continued from previous page.
SigmaWin+ SERVOPACK
Button in
Menu
Dialog Box
Name [Unit] Un No. Name [Unit]