2.4 Examples of Standard Connections between SERVOPACKs and Peripheral Devices
2-27
•
Linear Servomotor
*1. This example is for a SERVOPACK with a three-phase, 200-VAC power supply input. The pin layout of the main
circuit connector depends on the voltage.
*2. External Regenerative Resistors are not provided by Yaskawa.
CN8
Linear Servomotor
Ground
cable
CN3
CN5
CN7
CN1
CN2
Linear encoder
Sensor Cable
Linear Encoder Cable
Serial Converter Unit
Serial Converter Unit Cable
R S T
External
Regenerative
*2
Resistor
Noise Filter
Molded-case
circuit breaker
Magnetic Contactor
I/O Signal Cable
SERVOPACK
Power supply
Three-phase, 200 VAC
*1
Computer
Computer Cable
External
Regenerative
Resistor Cable
Control
Power
Supply Cable
Digital Operator
Digital Operator cable
Host controller
Analog Monitor Cable
Safety Function Device Cable
SERVOPACK
main circuit wires
Engineering Tool