6.1 Alarm Displays
6.1.2 Troubleshooting Alarms
6-17
A.740:
Inrush Current
Limiting Resistor
Overload
(The main circuit
power supply
was frequently
turned ON and
OFF.)
The allowable fre-
quency of the inrush
current limiting resis-
tor was exceeded
when the main circuit
power supply was
turned ON and OFF.
Reduce the frequency of
turning the main circuit
power supply ON and
OFF.
A failure occurred in
the SERVOPACK.
The SERVOPACK may be
faulty. Replace the
SERVOPACK.
A.7A1:
Internal Tempera-
ture Error 1
(Control Board
Temperature
Error)
The surrounding air
temperature is too
high.
Check the surrounding
air temperature using a
thermometer. Or, check
the operating status
with the SERVOPACK
installation environment
monitor.
Decrease the surround-
ing temperature by
improving the SERVO-
PACK installation condi-
tions.
*1
An overload alarm
was reset by turning
OFF the power sup-
ply too many times.
Check the alarm display
to see if there is an
overload alarm.
Change the method for
resetting the alarm.
There was an exces-
sive load or operation
was performed that
exceeded the regen-
erative processing
capacity.
Use the accumulated
load ratio to check the
load during operation,
and use the regenera-
tive load ratio to check
the regenerative pro-
cessing capacity.
Reconsider the load and
operating conditions.
The SERVOPACK
installation orientation
is not correct or there
is insufficient space
around the SERVO-
PACK.
Check the SERVOPACK
installation conditions.
Install the SERVOPACK
according to specifica-
tions.
*1
A failure occurred in
the SERVOPACK.
The SERVOPACK may be
faulty. Replace the
SERVOPACK.
Continued on next page.
Continued from previous page.
Alarm Number:
Alarm Name
Possible Cause Confirmation Correction Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA SIGMA-7 Series and is the answer not in the manual?

YASKAWA SIGMA-7 Series Specifications

General IconGeneral
Encoder Resolution24-bit absolute encoder
Pollution Degree2
Cooling MethodNatural cooling or forced air cooling
Control MethodVector control
Communication ProtocolsEtherCAT, MECHATROLINK-III
Input VoltageAC 200 V, AC 400 V
Rated OutputVaries by model
Safety FunctionSTO (Safe Torque Off), SS1 (Safe Stop 1), SS2 (Safe Stop 2), SLS (Safely Limited Speed), SBC (Safe Brake Control)
Power Supply VoltageAC 200 V, AC 400 V
Rated Output CurrentVaries by model
Protection FunctionsOverload, overvoltage, undervoltage, overheat, short circuit
Operating Temperature0°C to 55°C
Storage Temperature-20°C to 65°C
Vibration Resistance5.9 m/s² at 10 Hz to 55 Hz
Ambient Humidity5% to 95% RH (non-condensing)
AltitudeUp to 1000 m
InstallationPanel mounted