Administrators Guide for SIP-T2 Series/T19(P) E2/T4 Series/CP860 IP Phones
502
Parameters
Permitted Values
Default
Note: It is not applicable to SIP-T19(P) E2 IP phones.
Web User Interface:
DSSKey->Line Key->Type
Phone User Interface:
Menu->Features->DSS Keys->Line Key X->Type
linekey.X.value/
programablekey.X.value/
expansion_module.X.key.Y.value
String within 99
characters
Blank
Description:
Configures the multicast IP address and port number.
For line keys:
X ranges from 1 to 29 (for SIP-T48G).
X ranges from 1 to 27 (for SIP-T46G/T29G).
X ranges from 1 to 15 (for SIP-T42G/T41P).
X ranges from 1 to 21 (for SIP-T27P).
X ranges from 1 to 3 (for SIP-T40P/T23P/T23G)
X ranges from 1 to 2 (for SIP-T21(P) E2)
For programable keys:
X=1-6, 9, 13 (for CP860)
For ext keys:
X ranges from 1 to 6, Y ranges from 1 to 20, 22 to 40 (Ext key 21 cannot be
configured).
Example:
linekey.1.value = 224.5.5.6:10008
Note: The valid multicast IP addresses range from 224.0.0.0 to 239.255.255.255. It is
not applicable to SIP-T19(P) E2 IP phones.
Web User Interface:
DSSKey->Line Key->Value
Phone User Interface:
Menu->Features->DSS Keys->Line Key X->Value
linekey.X.label/
programablekey.X.label/
expansion_module.X.key.Y.label
String within 99
characters
Blank