Getting Started
57
The administrator or user wishes to clear user personalized configuration settings via
phone user interface.
Scenario Conditions:
SIP-T23G IP phone MAC: 001565770984
The current firmware of the phone is 44.80.0.60 or later.
Provisioning server URL: tftp://192.168.1.211
auto_provision.custom.protect = 1
Note
Scenario Operations:
You can clear the personalized settings of the phone via phone or web user interface.
To clear personalized configuration settings via phone user interface:
1. Press Menu->Settings->Advanced Settings (default password: admin).
2. Select Reset Local Configuration.
The LCD screen prompts “Reset local configurations?”.
3. Press the OK soft key.
The LCD screen prompts “Deleted successfully”.
To clear personalized configuration settings via web user interface:
1. Click on Settings->Upgrade.
2. Click Reset Local Config.
The Reset Local Configuration option on the web/phone user interface is available only if
the value of the parameter “auto_provision.custom.protect” was set to 1.
If the value of the parameter “auto_provision.custom.sync” was set to 1, the
configurations in the 001565770984-local.cfg file on the provisioning server will be also
cleared after resetting personalized settings of the phone.