User Preferences 3 - 23
HID CAPS Lock Override
Parameter # 1372
SSI # F8h 05h 5Ch
When enabled, the case of the data is preserved regardless of the state of the caps lock key. This setting is
always enabled for the “Japanese, Windows (ASCII)” keyboard type and can not be disabled.
HID Ignore Unknown Characters
Parameter # 1373
SSI # F8h 05h 5Dh
Unknown characters are characters the host does not recognize. When Send Bar Codes With Unknown
Characters is scanned, all bar code data is sent except for unknown characters, and no error beeps sound.
When Do Not Send Bar Codes With Unknown Characters is scanned, bar codes containing at least one
unknown character are not sent to the host, and an error beep sounds.
*Do Not Override Caps Lock Key (Disable)
(0)
Override Caps Lock Key (Enable)
(1)
*Send Bar Codes With Unknown Characters
(Enable)
(1)
Do Not Send Bar Codes With Unknown Characters
(Disable)
(0)