Symbologies 12 - 95
Escape Characters
Parameter # 233
SSI # E9h
This enables the backslash (\) character as an Escape character for systems that can process transmissions
containing special data sequences. Scan one of the following bar codes to either format special data according to
the GLI (Global Label Identifier) protocol, or to disable this parameter. This parameter only affects the data portion
of a Macro PDF symbol transmission; the Macro PDF Control Header (if enabled) is always sent with GLI
formatting.
Flush Macro PDF Buffer
Scan the following bar code to flush the buffer of all decoded Macro PDF data stored to that point, transmit it to the
host device, and abort from Macro PDF mode.
Abort Macro PDF Entry
Scan the following bar code to clear all currently-stored Macro PDF data in the buffer without transmission and
abort from Macro PDF mode.
GLI Protocol
(2)
*None
(0)
Flush Macro PDF Buffer
Abort Macro PDF Entry