4 - 22 DS2278 Digital Scanner Product Reference Guide
Decode Session Timeout
Parameter # 136
SSI # 88h
This parameter sets the maximum time decode processing continues during a scan attempt. It is programmable in
0.1 second increments from 0.5 to 9.9 seconds. The default timeout is 9.9 seconds.
To set a Decode Session Timeout, scan the following bar code, and then scan two bar codes from Appendix G,
Numeric Bar Codes that correspond to the desired on time. Enter a leading zero for single digit numbers. For
example, to set a Decode Session Timeout of 0.5 seconds, scan this bar code, and then scan the 0 and 5 bar
codes. To correct an error or change the selection, scan Cancel on page G-3
.
Hands-Free Decode Session Timeout
Parameter # 400
SSI # F0 90
This parameter is the hands-free compliment to the Decode Session Timeout. It configures the minimum and
maximum decode processing time during a hands-free scan attempt. It only applies to the hands-free trigger mode
or when a scanner is place in the gooseneck stand. The default is 15; range = 2 - 255.
The minimum decode processing time is defined as the time in which the scanner stops decoding when an object
is removed or left stationary in the imaging field of view.
The maximum decode processing time is defined as the time in which the scanner stops decoding when an object
is left in or is moving in the field of view.
Both the maximum and minimum times are configured using a single setting. The relationship of this setting is as
follows:
For example, a setting value of 100 results in the scanner turning off approximately 1 second after an object is
removed from the field of view or 10 seconds while an object is in the field of view moving.
The default value of the setting is 15 which results in a minimum time of 250 ms and maximum time of 2.5 seconds.
Adjust this setting based on your requirements. For example, when doing PDF prioritization, this parameter should
be set to a value where the maximum time is above the PDF prioritization timeout.
To set a three digit value scan the following bar code, and then scan three bar codes from Appendix G, Numeric
Bar Codes. Enter a leading zero for single digit numbers. To correct an error or change a selection, scan Cancel
on page G-3.
Decode Session Timeout
Setting Value
1
Minimum Time Maximum Time
X < 25 250 ms 2.5 Seconds
X >= 25 X * 10 ms X * 100 ms
1
Setting value must be three digits.
Hands-Free Decode Session Timeout

Table of Contents

Other manuals for Zebra DS2278

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra DS2278 and is the answer not in the manual?

Zebra DS2278 Specifications

General IconGeneral
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)5 - 95 %
Product colorWhite
LED indicatorsYes
Built-in displayNo
Housing material-
International Protection (IP) codeIP42
TypeHandheld bar code reader
Wavelength645 nm
Sensor typeLED
Scanner type1D/2D
Tilt reading angle-65 - 65 °
Motion tolerance (cm/s)13
Linear (1D) barcodes supportedCodabar, Code 11, Code 128, Code 39, Code 93, EAN-13, Interleaved 2 of 5, Plessey, U.P.C.
Optical sensor resolution (W x H)640 x 480 pixels
2D (matrix & stacked) barcodes supportedAztec Code, Composite Codes, Data Matrix, Han Xin, MaxiCode, Micro QR Code, PDF417, QR Code, TLC-39
Battery life84 h
Input voltage4.5 - 5.5 V
Battery capacity2400 mAh
Power source typeBattery, DC
Number of batteries supported1
USB version2.0
Bluetooth version4.0
Standard interfacesBluetooth, USB
Connectivity technologyWired & Wireless
Sustainability certificatesRoHS
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth90 mm
Width66 mm
Height175 mm
Weight214 g

Related product manuals