EasyManua.ls Logo

ABB ACQ810 - Page 147

ABB ACQ810
376 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters 147
13.24 AI5 max scale Defines the real value that corresponds to the maximum
analog input AI5 value defined by parameter 13.22 AI5 max.
-32768.000 …
32768.000
Real value corresponding to maximum AI5 value. 1000 = 1
13.25 AI5 min scale Defines the real value that corresponds to the minimum
analog input AI5 value defined by parameter 13.23 AI5 min.
See the drawing at parameter 13.24 AI5 max scale.
-32768.000 …
32768.000
Real value corresponding to minimum AI5 value. 1000 = 1
13.31 AI tune Triggers the AI tuning function.
Connect the signal to the input and select the appropriate
tuning function.
No action AI tune is not activated. 0
AI1 min tune Current analog input AI1 signal value is set as minimum
value of AI1 into parameter 13.03 AI1 min. The value reverts
back to No action automatically.
1
AI1 max tune Current analog input AI1 signal value is set as maximum
value of AI1 into parameter 13.02 AI1 max. The value reverts
back to No action automatically.
2
AI2 min tune Current analog input AI2 signal value is set as minimum
value of AI2 into parameter 13.08 AI2 min. The value reverts
back to No action automatically.
3
AI2 max tune Current analog input AI2 signal value is set as maximum
value of AI2 into parameter 13.07 AI2 max. The value reverts
back to No action automatically.
4
13.32 AI superv func Selects how the drive reacts when analog input signal limit is
reached. The limit is selected by parameter 13.33 AI superv
cw.
No No action taken. 0
Fault The drive trips on an AI SUPERVISION (0x8110) fault. 1
Spd ref Safe The drive generates an AI SUPERVISION (0x8110) alarm
and sets the speed to the speed defined by parameter 30.02
Speed ref safe.
WARNING! Make sure that it is safe to continue
operation in case of a communication break.
2
No. Name/Value Description FbEq
AI (scaled)
AI (mA/V)
13.24
13.22
13.23
13.25

Table of Contents

Other manuals for ABB ACQ810

Related product manuals