Replacing the auxiliary cooling fan of the drive module (frames R6 to
R9)
WARNING!
Obey the instructions in chapter Safety instructions. If you ignore them,
injury or death, or damage to the equipment can occur.
1.
Stop the drive and do the steps in section Electrical safety precautions (page 20) before
you start the work.
2. Open the cabinet door.
3. Unplug fan power supply wires from the drive.
4. Release the retaining clips.
5. Lift the fan off.
6. Install the new fan in reverse order.
Note:
Make sure that the arrow on the fan points up.
3
4
Replacing the circuit board compartment cooling fans (frames R10
and R11)
WARNING!
Obey the instructions in chapter Safety instructions. If you ignore them,
injury or death, or damage to the equipment can occur.
1.
Stop the drive and do the steps in section Electrical safety precautions (page 20) before
you start the work.
2. Open the cabinet door.
3.
Remove the drive module out of the cabinet as described in section Replacing the drive
module (frames R10 and R11) (page 154).
4. Undo the fastening screw of the fan enclosure.
5. Unplug the power supply cable of the fan.
6. Install the new fan in reverse order.