Layout of the cable entries (frames R6 to R9)
The layout of the input and motor cable connection terminals of frame R9 without du/dt filter
(option +E205) is shown below. The shrouds in front of the terminals are removed. The
layout is similar for the other frame sizes.
L1 L2 L3
1
1
U2
V2
W2
1
1
2
3
4 5
Input power cable terminalsL1, L2, L3
Motor cable terminalsU2, V2, W2
Strain relief1
PE (ground) terminal2
Emi-conductive cushion for grounding of the outer shields of the control cables3
Power cable entry4
Control cable entry5