NoteAction
Flange socket head screw with
glue: 3HAB3413-435
Secure the joint unit with new attachment screws.6
M4x35 12.9 Lafre
2C2B/FC6.9+PrO-COat111, with
NYPLAS glue , 12 pcs
Used for joint unit of CRB 15000-
5/0.95.
Always use new screws when refit-
ting a joint unit. If ordering a new
joint unit spare part, new screws
are included.
xx2000001943
xx2100000295
Remove the guide pins and secure the remaining
two attachment screws.
7
Pre-tighten the screws crosswise.8
Tightening torque: 4.3 Nm.Torque tighten all screws crosswise.9
xx2000001956
Remove the lifting aid by removing the screws.10
Clean pushed-out flange sealant, if any.11
Continues on next page
Product manual - CRB 15000 691
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.5.1 Replacing the base
Continued