Planning the electrical installation
34
3ADW000194R0611 DCS800 Hardware Manual f us
* F3.1 Fuse KTK25 included in FEX-425-Int inside D5 converter module
Fuses and fuse holders for 2-phase field supply
Single-phase Transformer T3 for field supply to match voltage levels
The field supply units’ insulation voltage is higher than the rated operating voltage
(see Chapter Field supplies), thus providing an option in systems of more than 500 V
for supplying the power section of the converter directly from the mains for purposes
of armature supply, and using an autotransformer to match the field supply to its
rated voltage. Moreover, you can use the autotransformer to reduce the voltage
ripple. Different types (primary voltages of 400...500 V and of 525...690 V) with
different rated currents each are available.
Autotransformer data (details see chapter Technical Data)
Field conv. Field
current
F3.1 F3.2 F 3.3
DCF803-0035 I
F
≤ 6 A 170M 1558 * OFAA 00 H10 10 A
FEX-425-Int * I
F
≤ 12 A 170M 1559 * OFAA 00 H16 16 A
DCF803 I
F
≤ 16 A 170M 1561 * OFAA 00 H25 25 A
DCF804 I
F
≤ 25 A 170M 1564 * OFAA 00 H25 35 A
DCF803 I
F
≤ 35 A 170M 1564 OFAA 00 H50 50 A
DCF804
DCF803 I
F
≤ 50 A 170M 1565 OFAA 00 H63 63 A
DCF804
Type of protection
elements
Semiconduct.
type fuse for
fuse holder
type OFAX 00
LV HRC type
for 690 V; fuse
hold. OFAX 00
circuit breaker
for 500 V or
690 V
Field converter type
≤500 V; 50/60 Hz
for field current
I
F
Transformer
type 50/60 Hz
external supply
U
prim
= ≤ 500 V
DCF803-0035
FEX-425-Int
≤ 6 A T 3.01
≤ 12 A T 3.02
≤ 16 A T 3.03
DCF803/4-0050 ≤ 30 A T 3.04
DCF803/4-0050 ≤ 50 A T 3.05
U
prim
= ≤ 600 V
DCF803-0035
FEX-425-Int
≤ 6 A T 3.11
≤ 12 A T 3.12
≤ 16 A T 3.13
U
prim
= ≤ 690 V
DCF803/4-0050
DCF803/4-0050
≤ 6 A T 3.11
≤ 12 A T 3.12
≤ 16 A T 3.13
≤ 30 A T 3.14
≤ 50 A T 3.15
utotransformer.dsf