Accessories
117
3ADW000194R0611 DCS800 Hardware Manual f us
RS232-Port
The RS232 interface is used for download the 'Field exciter firmware package'.
The firmware download is activated by setting S2:1-2 during auxiliary voltage is switched ON. Setting
for field exciter mode is S2:3-4 (default).
FEX425 INTERNAL (Fex-425-Int) Hardware configuration (size D5)
Further information about line reactors see sections Line reactor L3 (ND30) and Line reactors type
ND401...413 (ND402) in this chapter.
The default settings of this interface are as
follows:
Signal level: RS232
Data format: UART
Message format: Modbus-Protocol
Transmission method: half-duplex
Baudrate: 9.600 Baud
Number of Data bits: 8
Number of Stop bits: 1
Parity-Bit: odd
X2: Description
1 not connected
2TxD
3RxD
4 not connected
5 SGND Signal ground
6...9 not connected
V11
V24
V21
V14
1.4
2.1
2.4
1.1
2.6
V26
V13
1.3 2.3
1.6
V23
V16
2.2
V22
V15
1.5 2.5
1.2
V25
V12
K
G
K
G
G
K
G
K
G
K
G
K
G
K
K
G
K
G
G
K
K
G
G
K
V1 W1
C1 (+) D1 (-)
R11
C11
C24
F11
R13
C13
C26
F13
C15
C22
R15
F15
C14
C21
F14
R14
F16
C16
C23
R16
F12
C12
C25
R12
R57
R24 R21
R26
R22
R23
R25
PE
T51
P2
4000/1
4000/1
P1
T52
P2
P1
S1
S2
S1
S2
U1
HW conf FEX4.dsf
D1(-)
U1
V1
W1
SDCS-FEX-4
5A(+)
35A(+)
F301
F302
F303
U
V
W
L3K3
Plus code +S164
FEX425 INTERNAL
L1
Supply voltage max. 500 V
1- or 3-phase; for supply
voltages 500...600 V an
autotransormer is mandatory
V11
V24
V21
V14
1.4
2.1
2.4
1.1
2.6
V26
V13
1.3 2.3
1.6
V23
V16
2.2
V22
V15
1.5 2.5
1.2
V25
V12
K
G
K
G
G
K
G
K
G
K
G
K
G
K
K
G
K
G
G
K
K
G
G
K
V1
W1
C1 (+) D1 (-)
R11
C11
C24
F11
R13
C13
C26
F13
C15
C22
R15
F15
C14
C21
F14
R14
F16
C16
C23
R16
F12
C12
C25
R12
R57
R24 R21
R26
R22
R23
R25
PE
T51 P2
4000/1
4000/1
P1
T52 P2
P1
S1
S2
S1
S2
U1
HW conf FEX4.dsf
D1(-)
U1
V1
W1
SDCS-FEX-4
5A(+)
35A(+)
F301
F302
F303
U
V
W
L3
Plus code +S164
FEX425 INTERNAL
L1
Supply voltage
max. 600 V
K3
max. 500 V;
1- phase
1
9
5
6

Table of Contents

Other manuals for ABB DCS800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB DCS800 and is the answer not in the manual?

ABB DCS800 Specifications

General IconGeneral
Control TypeDigital
Supply Voltage380 ... 690 V AC
Input Voltage Range380 V to 690 V AC
Control ModeTorque, Speed
Cooling MethodAir-cooled
Communication ProtocolsModbus, Profibus, CANopen
Communication OptionsEthernet
Protection ClassIP21, IP54
Enclosure RatingIP00, IP21, IP54
ProtectionOvercurrent, Overvoltage, Overtemperature
Ambient Temperature0 to 40°C
Field SupplyIntegrated or External

Related product manuals