Note/IllustrationAction
Apply cable ties and suitable cable pro-
tection to ensure that the cables may not
be damaged by the door.
5
Concluding procedure
Note/IllustrationAction
Closing the door on page 185.Close the door.1
Restoring the hardware settings on page 236.Restore the hardware settings.2
Perform the function tests to verify that
the safety features work properly, see
Function tests on page 173.
3
Restoring the hardware settings
The controller hardware settings include information such as controller type and
serial number. When the main computer has been replaced, the serial number
must be restored before any software can be installed, or any licences can be
imported.
Note
When replacing the computer and logic unit, both the serial number and licences
are lost. The serial number must be restored as described below. Licences
however, can either be restored automatically when the RobotWare system is
installed, or manually through Manage Licences in RobotWare Installation
Utilities.
Note/IllustrationAction
Download the hardware information file
(hwsettings.rsf) from MyABB, or from a
previous system backup.
1
xx1900000110
Access the RobotWare Installation Utilit-
ies.
2
Tap Advanced, and then Restore Hard-
ware Settings.
3
The Restore Hardware Settings window
is displayed.
4
Follow the instructions and tap Next to
proceed.
Continues on next page
236 Product manual - OmniCore V250XT Type B
3HAC087112-001 Revision: A
© Copyright 2023-2023 ABB. All rights reserved.
5 Repair
5.2.8 Replacing the main computer
Continued