EasyManuals Logo

ABB X Series User Manual

ABB X Series
145 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #110 background imageLoading...
Page #110 background image
110 | XSE RIES G5 | 21060 2 6MN AA
Figure 10-12: Warm restart on the Station Setup tab (Expert view)
10.4.5 Warm restart using terminal mode
This procedure performs the warm restart from the terminal mode. It causes the device to restart
using the running (warm) configuration.
The procedure can be performed while physically connected to the device or remotely. Terminal mode
can be invoked from entry mode or from the PCCU splash screen. This method of warm restart
requires you to type a command.
To perform the warm restart:
Connect the PC running PCCU32 to the flow computer.
Select Entry mode within PCCU.
Click the Terminal icon on the PCCU toolbar.
Move the cursor to the terminal prompt (->)
Type in the following: ā€œBOOT=WARMā€.
Press Enter on the keyboard to initiate the warm boot.
10.4.6 Cold restart with onboard COLDBOOT button
This procedure uses the COLDBOOT and RESET buttons on the electronic board to restart a device. It
causes the device to restart using the startup (cold) configuration.
You must have physical access to the device and be able to open the enclosure door and access the
electronic board.
NOTICE - Loss of data: Perform the procedures in section 10.1 Preserve data and
configuration before a cold start. This avoids loss of the data and the need for a complete
system reconfiguration. If the startup (cold) configuration does not have the latest network
connection configuration, the restart causes loss of network connectivity. Updating the
startup configuration (tfCold) avoids loss of network connection and reconfiguration.
To perform a cold restart:
Open the door to the unit.
Locate the COLDBOOT button (S9) on the top left-hand side of the electronic board.
Locate the RESET button (XFC
G5
S2 and XRC
G5
S6) on the top left-hand side of the
electronic board.

Table of Contents

Other manuals for ABB X Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB X Series and is the answer not in the manual?

ABB X Series Specifications

General IconGeneral
BrandABB
ModelX Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals