10.4.4 Warm restart from PCCU entry mode ............................................................ 109
10.4.5 Warm restart using terminal mode ............................................................... 110
10.4.6 Cold restart with onboard COLDBOOT button ................................................. 110
10.4.7 Cold restart from the device loader .............................................................. 111
10.4.8 Cold restart from terminal mode .................................................................. 112
10.4.9 Restart using the factory configuration .......................................................... 113
10.5 Remove and restore power ....................................................................................... 114
10.5.1 Remove power from the electronic board ...................................................... 114
10.5.2 Reconnect power to the electronic board ....................................................... 115
10.6 Adjust the LCD contrast ........................................................................................... 115
10.7 XSeries
G5
replacement parts and procedures .............................................................. 116
10.7.1 Replace the 12 Vdc battery .......................................................................... 116
10.7.2 Replace the lithium battery.......................................................................... 117
10.7.3 Replace the XSeries
G5
electronic board .......................................................... 117
10.7.4 Replace the LCD assembly........................................................................... 118
10.7.5 Replace or add communication modules (COMM modules) ............................... 120
10.7.6 Replace the transducer (XFC
G5
only) ............................................................. 121
11 Calibration ................................................................................................................... 122
11.1 Measurement pressure checks and calibration ............................................................. 122
11.1.1 Static pressure checks ................................................................................ 122
11.1.2 Differential pressure checks ......................................................................... 123
11.1.3 Calibrating static pressure ........................................................................... 125
11.1.4 Calibrating differential pressure (DP) ............................................................ 126
11.2 Zero transducer ...................................................................................................... 127
11.2.1 Static pressure .......................................................................................... 128
11.2.2 Differential pressure ................................................................................... 128
11.3 RTD calibration ....................................................................................................... 128
11.4 Resistance temperature detectors (RTD) bias.............................................................. 130
11.5 Analog input calibration............................................................................................ 130
11.5.1 Connect calibration equipment ..................................................................... 131
11.5.2 Set the AI to the correct input signal mode ................................................... 131
11.5.3 Analog input calibration (voltage mode) ........................................................ 132
11.5.4 Analog input calibration (current mode) ........................................................ 134
11.5.5 Verify analog input calibration...................................................................... 136
11.5.6 Repeat calibration in case of errors ............................................................... 137
12 Troubleshooting ........................................................................................................... 139
12.1 LCD visual alarm and status codes ............................................................................ 139
12.2 Failure to start ........................................................................................................ 140
12.3 Screen locked-up .................................................................................................... 140
12.4 Remote communication failure .................................................................................. 141
Appendix A Typographical conventions ..................................................................... 142
Appendix B Cyber security ........................................................................................ 143
Appendix C Compliance ............................................................................................ 144
Contact us ........................................................................................................................ 145

Table of Contents

Other manuals for ABB X Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB X Series and is the answer not in the manual?

ABB X Series Specifications

General IconGeneral
BrandABB
ModelX Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals